  • 2024-04-16 How to solve the problem of yellow water discharge of softening water equipment? Softened water equipment is widely used in daily life, but sometimes its water will turn yellow, causing inconvenience to users. This situation may be caused by scale, iron oxide and other reasons caused by long-term operation of the equipment. However, there are steps we can take to address this problem. First, you can try to clean the softened water equipment. Users can choose professional cleaning agents, according to the requirements of the manual cleaning, the equipment inside the scale and dirt clean, so as to improve the quality of water. Secondly, a pre-filter can be added. Before the water enters the softened water equipment, adding a pre-filter can effectively block the impurities and dirt of large particles, reduce the burden of the equipment, and thus improve the quality of the effluent. In addition, the operating parameters of the softened water equipment can also be adjusted appropriately. According to the local water quality and use situation, adjust the brine concentration, recovery rate and other parameters of the equipment, can achieve better softening effect and effluent quality. Finally, the softened water equipment needs to be maintained regularly. Check the operating status of the equipment regularly, replace the filter element and resin in time, clean the inside of the equipment, and prevent the scale and dirt caused by long-term use from affecting the quality of the water. In short, the problem of yellow water of the softening water equipment is not without solution, through cleaning e
  • 2024-04-12 Hebei Chengda Water Treatment Technology Co., Ltd. invites you to visit the 26th Shandong International Water Exhibition 2024 Hebei Chengda Water Treatment Technology Co., Ltd. (abbreviated: Chengda Water Treatment Technology) is a high -tech enterprise engaged in the research and development, production and sales of water treatment environmental protection products.   Its registered trademark brand: Winder® Win, Cenhon® Navigation, ArcLION® Aklin, Winder®-G, AOWY®. Its brand product: water treatment frp reinforced fiber housing shell, sea light high -pressure glass fiber steel membrane shell, ST/DTRO membrane shell, tubular membrane shell, glass fiber reinforcement filter, special membrane shell, quick -disassembly membrane shell, RO reverse osmosis membrane, RO reverse osmosis membrane film Components; Water Treatment of FRP composite tanks, glass fiber reinforcement (customized) tanks, mixed beds (ion exchange columns), PE salt tanks, waterfish, oxygen cone, glass fiber reservoir storage tank, filter sand tank, ion exchange resin, ion exchange resin , Filter material and other one -stop water treatment manufacturers.   Chengda Shui Treatment Technology takes "using technology to purify the world of water" as its corporate purpose. Our R & D team and Wuhan University of Science and Technology are united to use more advanced equipment and production processes to create international excellent products.   Products have passed EU CE certification, US NSF certification, international ISO9001 quality management system certification, international ISO14001 environmental management system certification, and domestic health license approval certification; Specialized new "SMEs, won the Certificate of Science and Technology Achievement of Hebei Province, Hebei Outstanding Brand, Hengshui
  • 2024-04-07 The necessity of pre -treatment of industrial reverse osmosis equipment The pre -processing of industrial reverse osmosis equipment is a vital link. The pre -processing is well done, and the reverse osmosis equipment can exert the maximum effect and ensure that the water quality is pure and safe. So why is pre -processing so important?   The pre -processing process can effectively improve the work efficiency of reverse osmosis equipment and the life of the equipment. Through pre -treatment, the suspended solids, organic substances, bacteria and viruses in water can be effectively removed to protect the reverse osmosis membrane from pollution and damage. This can not only improve the quality of water production, but also reduce energy consumption and maintenance costs. Imagine that if the impurities enter the reverse osmosis membrane, it will not only shorten its service life, but also affect water quality and cause a series of problems. At the same time, pre -processing can also adjust the pH value and temperature of water, creating the best conditions for the reverse osmosis process. In this way, reverse osmosis equipment can work more efficiently to ensure that the water quality of the output meets the standard.   In addition, pre -treatment can also reduce the number of cleaning and replacement frequency of reverse osmosis membranes, and can also reduce the failure rate during the operation of the reverse osmosis equipment, and improve the stability and reliability of the equipment. Appropriate pre -treatment measures can effectively reduce the pollution of reverse osmosis membranes, extend the service life of reverse osmosis equipment, reduce maint
  • 2024-03-28 Water Softening Equipment resin regeneration process When the resin in the softener is saturated, regeneration needs to be performed to restore the resin exchange ability. The regeneration process of the resin is divided into smooth regeneration and reverse regeneration according to the flow of the recycled salt fluid. The recycled salt fluid flow is called smooth regeneration when the runtime flow is the same as running raw water. There are main steps such as anti -washing, regeneration, replacement, and positive washing in the regeneration process of the softener. (1) Anti -cleaning process After the resin fails, it is necessary to use anti -wash water to use the bottom -up washing. The anti -washing process can remove impurities such as suspension and crushing resin in the resin layer, which can destroy the resin plate. It is best to use the softened water that has been softened, and the effect of anti -washing with the original water of the system is poor. The anti-washing speed is about 10m/h, and the anti-washing time is 10-15min.     (2) Regeneration process After the anti -washing process is over, the regeneration process should be entered. The renewal process of resin follows the principles of material exchange. During the regeneration process, the concentration of the regenerative salt fluid should be kept at 5%-10%, and the flow rate of the recycled solution should be controlled at 6-8m/h. The regeneration effect is very sensitive to the hardness of the regenerative solution. You should try to use the softened water for the recycled solution. In particular, the high -hardness raw water should be avoide
  • 2024-03-22 Hebei Chengda Water Treatment Technology Co., LTD. HeBei ChengDa Water Technology Co., Ltd. (Abbreviation: Chengda Water Technology), was found in 1976 and is a professional company specializing in the production and export of FRP pressure vessels. Factory covers an area of 20 acres and has 200 employees, have a professional team of engineers. We are a high-tech enterprise engaged in water treatment products research and development, production and sales. Products we produce include water treatment FRP RO membrane housing, desalination
  • 2024-03-14 What do you need to pay attention to when installing double tank softened water equipment ? The double tank softened water equipment is mainly composed of two resin tanks and a salt tank controlled by a control valve. A valve controls the two tanks and is equipped with two pistons, one to control the regeneration process and the other to switch between the two tanks and provide a continuous supply of softened water. What do you need to pay attention to when installing the can softening water equipment? Note the following when installing the two-tank softened water device 1. The equipment needs a simple horizontal foundation, about 250 ~ 450mm away from the wall, which can be arranged near the corner according to the actual situation; 2. Because the equipment itself is light, generally only the weight of the resin and water installed in the equipment can be considered; 3. The inlet and outlet pipes are standard flanged or threaded connections, which need to be fixed and supported, and cannot be supported by the valve body to prevent stress; 4. Y-type filter and water pressure gauge should be installed on the water inlet pipe to prevent the dirt in the water inlet pipe from blocking the controller. When the equipment is running, the flushing water is discharged, and the floor drain or drainage ditch is set nearby; 5. The salt water tank should be as close as possible to the softening tank, and the shorter the brine pipe, the better; 6. The sewage
  • 2024-03-05 Why does the reverse osmosis water treatment equipment have unstable water pressure? There are many reasons if the water pressure is unstable during operation during the operation of the reverse osmosis and water treatment equipment. If you take measures without knowing the specific reasons, it is difficult to effectively solve the problem, so this article is for this article. It is said that there is an unstable water pressure in the reverse osmosis and water treatment equipment. 1. The water flow velocity is not appropriate. 2. System leakage. 3. Insufficient water pressure in the entrance of the high -pressure pump or leakage and air leakage of the pump. 4, precision filter filter element stain. 5. High -pressure pump failure. The above is the introduction of the reasons for the unstable water pressure of the reverse osmosis equipment. In actual use, if the water pressure of your reverse osmosis and water treatment equipment also appears, you can check it one by one according to the above method, and find the corresponding solution to the corresponding solution. Intersection
  • 2024-02-28 How long is the service life of the resin? Soft -sources are a resin used for hard water softening, which can remove calcium and magnesium ions in water and achieve the purpose of softening water. Softening resin has a certain service life as other consumables. This article takes you to understand the service life of softening resin, so that everyone can have a deeper understanding of the soft -span resin before use. Usually high-quality softened water resin, such as the use of soft-used resins of imported brands in 3-5 years, but in actual operation, resin will be affected by some factors. The service life of the general domestic softening resin will be shorter, usually 1-2 years. However, in actual use, it is still necessary to determine according to the water quality of the water. If the raw water is too large and the resin is overloaded, the resin replacement frequency needs to be increased. 1. Because the raw water pipeline is usually a carbon steel pipe, the oxidation reaction occurs in water and pipelines, the generated iron ions are generated, and the function exchange group of the resin after entering the resin decreases with the extension of the operation time. Poor regenerative water quality. 2. Repeated resin: Due to the frequent regeneration of the resin for a long time, each time the resin is scrubbed, the mechanical wear between the resin and the mechanical wear between the resin, the cross -linking value (mechanical strength) of the resin will gradually decrease. The skeleton deformation, during operation, it appears to be yellow, and the water production cycle is significantly shortened, resulting in the ultimate regeneration effect is not ideal. Over time, there are many factors that reduce the performance of softening water resin. However, we can take some measures to improve performance and extend the service life of the system. By installing the activated carbon filter before the floppy water heater, chlorine and chloride can be removed
  • 2024-02-20 Introduction to the work principle of Water Distributor Water is a waterwater device that is evenly arranged in a certain working area according to the law and completes the mission of this task. The editor of this article is about what the working principle of the clothing device is. Common clothing machines are perforated tube, nozzle, filter head, and rotating cloth water. For example, the cloth water heater in the sand filter is composed of a dry pipe-branched pipe-cloth water hole. The lower side of each branch of the tube is evenly arranged in small pores of the diameter of the equal pores. When you go to the support, then rinse the sand evenly from the pore eye of the support. The rotating fabric is a perforated tube that can rotate, and it is often used in water treatment. The function of the waterfall system is to splash water evenly on the entire pour. The performance of the distribution of water distribution will directly affect the uniformity of air distribution and the ability to cool up. The above is the introduction of the working principle of the clothing device. Nowadays, the cloth water heater can be widely used in mechanical filtering equipment, activated carbon filtering equipment, softening water treatment equipment, except for saline equipment.
  • 2024-02-17 Summary water treatment equipment and equipment knowledge summary Let's take a look at what softened water is. In daily life, we often see that the inner wall will produce scale after long -term use of kettles. what is the reason? It turns out that the water we take contains a lot of inorganic salts, such as calcium and magnesium salt. The naked eye can't find these salt in room temperature water. Once heated and boiled, many calcium and magnesium salts will precipitate in carbonate, and scald will form near the pot wall. The content of calcium and magnesium ions in water is usually represented by hardness indicators. Hardness 1 degree is equivalent to 10 mg of calcium oxide per liter. Water below 8 degrees is called soft water, water above 17 degrees is called hard water, and water between 8 and 17 degrees is called moderate hard water. Rain, snow, rivers, and lakes are soft water, and spring water, deep well water, and sea water are hard water. Let's take a look at the difference between other water for softened water Original water refers to unprocessed water. In a broad sense, water before entering the water treatment process is also called water treatment raw water. For example, the water from the water source is called raw water. Sofele water refers to the hardness in water (mainly calcium and magnesium ions in water). During softening, the water is reduced, and the total salt content is unchanged. Except salt water refers to the removal or reduction of salt in water (mainly strong electrolytes dissolved in water). Its conductivity is generally 1.0 ~ 10.0 μs/cm, the resistivity (25 ° C) (0.1 ~ 1.0) × 106 · cm, and the salt content is 1 ~ 5mg/L. Pure water refers to the strong electrolytes and weak electrolytes in the water (such as SIO2.CO2, etc.). ) It is removed or reduced to the degree. Its conductivity is generally: 1.0 ~ 0.1
  • 2023-11-15 What is the service life of softened resin? Softening Resin is a resin used to soften hard water. It can remove calcium and magnesium ions in the water to achieve the purpose of softening the water. Softened resin, like other consumables, has a certain service life. This article will take you through the service life of softened resin so that you can have a deeper understanding of softened resin before use. Water Softener Resin is a resin used to soften hard water. It can remove calcium and magnesium ions in the water to achieve the purpose of softening the water. Softened resin, like other consumables, has a certain service life. This article will take you through the service life of softened resin so that you can have a deeper understanding of softened resin before use. Service life of softened resin Generally, high-quality water softening resins, such as imported brands of softening resins, have a service life of 3-5 years. However, in actual operation, the resin will be affected by some factors. Generally, the service life of domestic softening resin will be shorter, usually 1-2 years. However, in actual use, it still depends on the quality of the treated water. If the hardness of the raw water is too high and the resin is overloaded, the frequency of resin replacement needs to be increased. What factors affect the service life of softened resin? 1. Since raw water pipelines are usually carbon steel pipelines, an oxidation reaction occurs between the water and the pipeline to generate iron ions. After entering the resin, the functional exchange groups of the resin decrease with the extension of the operating time, which is
  • 2023-11-08 Introduction to the advantages of mixed ion exchange equipment Mixed ion exchange equipment, referred to as mixed bed, is equipment designed for ion exchange technology. The so-called mixed bed is to mix and load a certain proportion of cation and Anion Exchange Resin in the same exchange device to exchange and remove ions in the fluid. This article will talk about some advantages of hybrid ion exchange equipment. The advantages of mixed ion exchange equipment are as follows: 1. The effluent water quality is excellent, and the effluent pH value is close to neutral. 2. The effluent water quality is stable, and short-term changes in operating conditions (such as inlet water quality or components, operating flow rate, etc.) have little impact on the mixed bed effluent water quality. 3. Intermittent operation has little impact on the effluent quality, and the time required to restore the water quality to before the shutdown is relatively short. 4. The recovery rate reaches 100%. The above is an introduction to the advantages of mixed ion exchange equipment. Mixed ion exchange equipment is also divided into in vivo synchronous regeneration mixed bed and external regeneration mixed bed. The operation and the entire regeneration process of the synchronous regeneration mixed bed are carried out in the mixed bed. The Resin does not move out of the equipment during regeneration, and the anode and anion resins are regenerated at the same time. Therefore, it requires less ancillary equipment and is easy to operate.
  • 2023-11-03 How to correctly add salt to softened water equipment to maintain resin circulation and regeneration? Softened Water Treatment Equipment mainly uses Ion Exchange Resin to remove hardness ions such as calcium and magnesium in the water. When the ion exchange resin is saturated, it needs to be regenerated. At this time, the salt in the salt box is regenerated. However, some customers do not know much about the correct method of adding salt to softened water equipment. In this article, the editor will introduce to you the correct method of adding salt to softened water equipment. The correct method of adding salt to softened water equipment is as follows: 1. The amount of salt added is the amount of resin (L) multiplied by 0.24Kg, which is the amount of salt used; 2. The time for adding salt should be consistent with the resin regeneration cycle; 3. It is strictly prohibited to use industrial salt and iodized salt. Iodine has strong penetrating power on the surface of resin particles. Long-term use of iodized salt will reduce the surface strength, hardness, mechanical strength, volume expansion strength, and circular curvature of the resin. Easily broken, the exchange capacity of the resin is reduced (referring to strong acid resin); 4. It is recommended that you put the salt into a pure cotton bag, tie it up, and put it in the Brine Tank, which can effectively prevent the pollution of the salt box and blockage of the salt absorption system caused by insoluble particles; 5. The water level of the salt box after adding salt should not be lo
  • 2023-11-01 Introduction to installation precautions for softened water equipment Softened water equipment is a Water Treatment System used to soften water. Its main function is to remove calcium and magnesium ions in the water to produce soft water. This article will talk about some matters that need to be paid attention to when installing softened water equipment. The installation precautions for softened water equipment are as follows: 1. The softened water equipment must be installed on a solid horizontal surface, and there should be drainage pipes nearby. 2. The salt tank should be placed close to the Resin tank. In order to increase the salt absorption rate, the length of the salt absorption pipe should be shortened as much as possible. 3. Filling quartz sand: Before filling, the central tube should be placed in the center of the resin tank, then quartz sand should be put in, and the sand layer should be paved at the bottom of the tank. 4. Filling resin: Put the processed resin into the resin tank according to the approved filling amount. 5. Align the upper end of the central tube with the socket in the center of the bottom of the control valve, and carefully turn the control valve clockwise (note: during the installation of the control valve, be sure to ensure that the central tube is inserted into the valve body) until the control valve is tight. On the tank. 6. Connect the pipes and power supply as shown in the installation schematic diagram. 7. When starting the softene
  • 2023-10-31 Correct storage method after reverse osmosis shutdown Storage of membrane elements Store the components in a cool, dry warehouse, or package them for storage. The minimum temperature should be higher than 5°C, and it is best to keep it at 10-20°C. Preservation of membrane systems 1.Short-term storage No flushing is required within 2 hours of shutdown; If the machine is shut down for more than 2 hours, perform RO product water flushing for 20 minutes; 2. Medium-term storage If the machine is shut down for 3 days or more and within 30 days, follow the steps below to save: (1) Cleaning-in-line (CIP) RO Membrane element; (2) Use RO produced water to rinse for more than 30 minutes; (3) When the flushing is completed, keep the membrane in the flushing water (RO product water) and close the valve to keep the solution in the RO section; (4) Perform steps 2 and
  • 2023-10-24 Four major measures to prevent water hammer damage during reverse osmosis operations "Water hammer" is caused by air mixed in the pressure vessel. When starting the device, necessary means are not used to remove the air in the vessel, so that when the high-pressure water flow mixed with air moves into the vessel, it will produce violent vibrations. In severe cases, it will The Membrane Element will be smashed into pieces, causing irrecoverable losses. Common preventive measures are: (1) High-pressure pumps should be avoided by using soft-start methods, such as voltage reduction start, variable frequency speed regulation start, and series resistance start with automatic controller. (2) Avoid operating methods, such as closing or reducing the inlet valve at startup, and then slowly opening the valve until the system working pressure is reached. (3) Use control to prevent and avoid, such as using PLC to control an electric slow door opening to open the valve within tens of seconds. (4) Use installation techniques to prevent this, such as setting up a return pipe at the concentrated water discharge port so that the highest point of the pipe exceeds the highest pressure vessel in the reverse osmosis device, so that the pressure vessel will be filled with water when the device stops operating. The above points are commonly used measures in engineering applications. You can adopt all of them or adopt several points according to the actual situation. It is worth noting that point 4 is necessary no matter which project.
  • 2023-10-17 Countermeasures for reverse osmosis operation in winter Effect of low temperature on RO performance 1. Water flux Normally, for every 1 degree change in temperature, the water production volume changes by about 3%, this is mainly due to changes in the viscosity of water. (Higher water temperature) Low water viscosity is more conducive to water flow through the membrane, that is: water flux changes with temperature decreases. 2. Desalination rate The decrease in water temperature will increase the desalination rate of the system (different types of membrane elements have different degrees of increase), which means an improvement in the quality of the produced water. Note: The above discussion of the impact of temperature on the membrane system refers to the same operating conditions, that is, the same raw water salt content, pH, system operating pressure and recovery rate, etc. How to avoid the impact of low temperature on the RO system Based on the above, the impact of low temperature on the RO system is mainly the lack of system output caused by reduced water flux. So how to avoid it? Generally speaking, there are the following ways: 1. Increase the temperature of raw water Since low water temperature causes a reduction in RO System water flux, the most direct way to solve this problem is to increase the raw water temperature.
  • 2023-10-10 Why does the Ro System need pre-treatment? Ro System are widely used in the water treatment industry. Ro Equipment often require pre-treatment because the impurities contained in the raw water will contaminate the Membrane Element and affect the stable operation of the system and the service life of the membrane elements. The reasons for adding pretreatment to the reverse osmosis system are as follows: 1. Prevent contamination on the membrane surface, that is, prevent suspended impurities, microorganisms, colloidal substances, etc. from adhering to the surface or fouling the flow channels of the membrane elements. 2. Prevent scaling on the membrane surface. During the operation of the reverse osmosis device, due to the concentration of water, some insoluble salts such as CaCO3, CaSO4, BaSO4, SrSO4, CaF2, etc. are deposited on the membrane surface, so the generation of these insoluble salts must be prevented. 3. Ensure that the membrane is protected from mechanical and chemical damage so that the membrane has good performance and a long enough service life.
  • 2023-10-04 What is the reason why reverse osmosis equipment makes loud noise? How to solve it? Ro Equipment generally works indoors. If the operator works around the equipment for a long time, he will definitely hear the sound made by the equipment. Under normal circumstances, the sound of the reverse osmosis equipment is not very loud and is acceptable. However, if you hear a very loud noise coming from your device it may be time to look into the cause. So how should we deal with this larger noise to better reduce the noise problem of the equipment? The core of the reverse osmosis equipment is the Ro Membrane. The water treatment technology of the entire equipment revolves around reverse osmosis. After the raw water is pressurized by the high-pressure pump, the raw water passes through the reverse osmosis membrane and becomes purified water. The water contained in the raw water Minerals and some impurities will be discharged through the concentrated water discharge valve with high pressure. After the raw water is pressurized, the pressure is about 0.8 MPa, and the water flows in a high-speed rotating manner, which will produce very loud noises, especially in the throttle valve part that discharges concentrated water. The concentrated water discharge shut-off valve plays a very important role in equipment production. It can adjust the ratio of water production and concentrated water discharge, and adjust the pressure and noise during the overall operation of the equipment. After the concentrated water is intercepted by the regulating valve, the space will suddenly increase due to the action of the regulating valve itself, and the high-speed rotating water will produce very harsh noises.
  • 2023-09-29 Basic operating steps for mixed bed operation 1. Washing Start the intermediate water pump, open the mixed bed water inlet valve and exhaust valve, and flow water from top to bottom. When the water flow reaches the equipment, close the exhaust valve and open the lower exhaust valve to stabilize its normal water production flow. The working flow rate is 35m/h, and the water outlet If the lead is ≤0.2μs/cm, it will switch to water production. 2. Water production Open the mixed bed water outlet valve, close the lower discharge valve, and stabilize the water production to the specified set value until the water production cycle ends. 3. Regeneration (1) Backwash pre-stratification: Open the backwash water inlet valve and the upper discharge valve, and perform backwash stratification at a flow rate of 10m/h, or keep the Resin in a fully flowing state so that the normal particle resin is not flushed out by the water flow. It is advisable to control the backwash flow until the end point of backwash is when the anin and cation resins are basically stratified. (2) Failure: Open the alkali regeneration water dilution valve, alkali metering box outlet valve, mixed bed alkali inlet valve and lower discharge valve, start the regeneration pump, the flow rate is preferably controlled at 5m/h, the time is 5 minutes, and the regeneration water temperature is 40~ 50℃. Note: (1) and (2) are only used when the Mixed Bed Resin has been used for a long time and is seriously polluted and the layers are unclear. (3) Backwash stratification: Open the backwash water inlet valve and the upper discharge valve, and perform backwash stratifica
  • 2023-09-25 What should you pay attention to when installing double-tank softened Water Treatment Equipment? The double-tank softened Water Treatment System mainly consists of a control valve controlling two resin tanks and a salt tank. One valve controls two tanks and is equipped with two pistons. One piston is used to control the regeneration process, while the other piston switches between the two Frp Tank and can continuously supply softened water. What should you pay attention to when installing double-tank softened water equipment? The following issues need to be paid attention to when installing double-tank softened water equipment: 1. The equipment needs a simple horizontal foundation, about 250~450mm away from the wall, and can be arranged at the corner according to the actual situation; 2. Because the equipment itself is relatively light, generally you only need to consider the weight of the resin and water contained in the equipment; 3. The inlet and outlet pipes are standard flange or threaded connections and need to be fixed and supported. They cannot rely on the valve body for support to prevent stress; 4. A Y-type filter and a water Liquid Filled Pressure Gauge should be installed on the water inlet pipe to prevent dirt in the water inlet pipe from clogging the controller. If flushing water is discharged when the equipment is running, a floor drain or drainage ditch should be installed nearby; 5. The Brine Tank should be as close as possible to t
  • 2023-09-18 Introduction to the working principle of water distributor Water Distribution is to arrange the amount of water evenly and regularly on a certain working area, and the device that completes this task is called a Water Distributor. Common water distributors include perforated pipes, nozzles, filters, and rotating water distributors. For example, the water distributor in a sand filter is composed of a main pipe - a branch pipe - a water distribution hole. There are many small holes of equal spacing and equal diameters evenly arranged on the underside of each branch pipe. The water for backwashing of the filter flows through the main pipe. to the branch pipe, and then flow out from the holes of the branch pipe upward to evenly flush the filter sand. Rotating water distributors are perforated tubes that can rotate and are often used in water treatment. The function of the water distributor in the Water Treatment Equipment is to splash water evenly onto the entire water filling material. The performance of water distribution will directly affect the uniformity of air distribution and the ability of the filler to exert a cooling effect. The above is an introduction to the working principle of the water distributor. Nowadays, water distributors can be widely used in mechanical filtration equipment, activated carbon filtration equipment, softened Water Treatment System, and demineralized water equipment.
  • 2023-09-12 An introduction to the reasons why softened water equipment does not produce soft water or does not operate Softened water equipment It is mainly used to remove hardness ions such as calcium and magnesium in water and reduce the generation of scale. So what is the reason why the softened water equipment does not produce soft water or does not operate? When the softened water equipment does not produce soft water during operation, you must first consider whether the bypass valve is not open and whether the resin is leaking. If this is the case, you need to open the bypass valve and check whether the resin tank is damaged. If If there is not enough salt in the salt box, you need to add salt to the salt box. If the softened water equipment does not operate during operation, the power system needs to be observed so that the equipment can be powered on normally. If a water pipe breaks, the pipe must be replaced. In daily life, the use of water softening equipment is also relatively common. The above is an introduction to the reasons why the softened water equipment does not produce soft water or does not operate. As we all know, if the hardness of household water is too high, scale will easily occur. If it is an electric boiler, its heat conversion efficiency will directly affect the quality of the electric boiler, so it is very necessary to install a softened water equipment.
  • 2023-09-08 Introduction to maintenance methods of Frp resin tanks The Frp Pressure Tank is made of high-performance resin and glass fiber winding and lined with PE liner, which is non-toxic and hygienic. And because of its high strength, light weight, and beautiful appearance, it has been widely used in various fields such as petroleum, electronics, light industry, food, and beverages.Let`s talk about the maintenance methods of fiberglass resin tanks. How to maintain fiberglass resin tanks is as follows: 1. Ensure that the input voltage and pressure of the softened water equipment or multi-media filter is stable to avoid the instantaneous negative pressure caused by the equipment causing the FRP Tank to burst. 2. When not in use in winter, antifreeze measures should be taken to prevent the fiberglass tank from cracking and breaking, and to ensure that the indoor temperature is between 0-45°C. 3. The fiberglass resin tank must be installed in a sunny and dark place indoors to prevent the tank from cracking due to long-term strong light exposure. The above is an introduction to the maintenance methods of Frp Softener Water Tanks. Many users neglect maintenance during daily use, resulting in shortened service life and abnormal operation of fiberglass tanks. Therefore, for the benefit of users, the editor recommends that you check regularly, pay attention to maintenance, and store reasonably to avoid unnecessary losses and waste.